{"product_id":"doosan-dx210-and-dx225lcb-excavator-service-manual-workshop-guide","title":"Doosan DX210 and DX225LCB Excavator Service Manual Workshop Guide","description":"Format : PDF\u003cbr\u003eSUPPLIED AS DOWNLOADABLE LINK\u003cbr\u003e\u003cbr\u003eManual Included:\u003cbr\u003eShop Manual:\u003cbr\u003e792 Pages\u003cbr\u003eSpecifications:\u003cbr\u003eBrand:\u003cbr\u003eDoosan Excavator\u003cbr\u003eModel:\u003cbr\u003eDX210 and DX225LCB\u003cbr\u003eSerial Number:\u003cbr\u003e5001 and Up\u003cbr\u003eType:\u003cbr\u003eExcavator\u003cbr\u003eManuals:\u003cbr\u003eShop Manual\u003cbr\u003ePublication Number:\u003cbr\u003e950106-00185E\u003cbr\u003eLanguage:\u003cbr\u003eEnglish\u003cbr\u003eFormat:\u003cbr\u003ePDF\u003cbr\u003e\u003cbr\u003eDescription\u003cbr\u003eTable of Contents:-\u003cbr\u003eSafety\u003cbr\u003eTrack Excavator Safety …………………………………………………………….. SP002125\u003cbr\u003eSpecifications\u003cbr\u003eSpecification for DX210\/225LCB………………………………………………… SP002126\u003cbr\u003eGeneral Maintenance\u003cbr\u003eGeneral Maintenance Procedures ……………………………………………… SP000016\u003cbr\u003eStandard Torques …………………………………………………………………….. SP000813\u003cbr\u003eUpper Structure\u003cbr\u003eCabin ………………………………………………………………………………………. SP002127\u003cbr\u003eCounterweight…………………………………………………………………………… SP001617\u003cbr\u003eFuel Tank………………………………………………………………………………… SP001718\u003cbr\u003eFuel Transfer Pump …………………………………………………………………. SP000021\u003cbr\u003eSwing Bearing………………………………………………………………………….. SP000022\u003cbr\u003eSwing Reduction Gear ……………………………………………………………… SP001618\u003cbr\u003eLower Structure and\u003cbr\u003eChassis\u003cbr\u003eTrack Assembly ……………………………………………………………………….. SP002128\u003cbr\u003eEngine and Drive Train\u003cbr\u003eDrive Coupling (Main Pump) …………………………………………………….. SP000912\u003cbr\u003eHydraulics\u003cbr\u003eHydraulic System Troubleshooting, Testing and Adjustment ……….. SP002170\u003cbr\u003eAccumulator……………………………………………………………………………… SP000028\u003cbr\u003eCenter Joint (Swivel) ………………………………………………………………… SP001620\u003cbr\u003eCylinders………………………………………………………………………………….. SP002129\u003cbr\u003eSwing Motor …………………………………………………………………………….. SP000194\u003cbr\u003eTravel Motor…………………………………………………………………………….. SP001621\u003cbr\u003eGear Pump………………………………………………………………………………. SP000931\u003cbr\u003eMain Control Valve…………………………………………………………………… SP001024\u003cbr\u003eAxial Piston Pump……………………………………………………………………. SP000932\u003cbr\u003ePTO Server ……………………………………………………………………………… SP000933\u003cbr\u003eRemote Control Valve (Work Lever \/ Joystick) ………………………….. SP001646\u003cbr\u003eTravel Control Valve (with Damper) ………………………………………….. SP001647\u003cbr\u003eSolenoid Valve Assembly………………………………………………………….. SP001622\u003cbr\u003eBreaker EPPR Valve (Opt)……………………………………………………….. SP000192\u003cbr\u003eHydraulic Schematic (DX210\/225LCB) ……………………………………….. SP002173\u003cbr\u003eElectrical System\u003cbr\u003eElectrical System ……………………………………………………………………… SP002131\u003cbr\u003eElectrical Schematic (DX210\/DX225LCB) …………………………………… SP002132\u003cbr\u003eAttachments\u003cbr\u003eBoom and Arm………………………………………………………………………… SP002133\u003cbr\u003eBucket……………………………………………………………………………………… SP000939\u003cbr\u003eDoosan DX210 and DX225LCB Manual Instruction Extract:\u003cbr\u003eSTART-UP PROCEDURES\u003cbr\u003e1. Before operating machine, make sure that oil passages and hydraulic oil are clean.\u003cbr\u003e2. Hydraulic oil of which annealing point is 82 – 113C (180 – 235F) should be used in the hydraulic system.\u003cbr\u003e3. Relief valve pressure should not be raised above specified pressure setting.\u003cbr\u003e4. The difference between main relief valve setting pressure and overload relief valve setting pressure should not be over 2.0 MPa [20.39 kg\/cm2 (290 psi)].\u003cbr\u003e5. Before operating machine, the hydraulic system should be fully warmed up. If machine is operated with cold hydraulic oil and valve, be careful of the following, to prevent spool sticking due to heat shock.\u003cbr\u003eNOTE: Do not operate main relief valve or overload relief valve suddenly and continuously. Cycle oil through all actuators and warmed up cold hydraulic oil in the lines and components uniformly.\u003cbr\u003eNOTE: Slight or compound work should not be suddenly operated at cold weather because heat is developed partly at all the orifices.\u003cbr\u003eHow to Use The Doosan DX210 and DX225LCB Excavator Guide Manual:\u003cbr\u003eThis manual provides information for servicing the DX210 and DX225LCB Doosan Excavator. All service procedures are broken down into detailed steps, listed in their recommended sequence. The manual uses both photographs and drawings to help locate and itemize components. The table of Contents on the preceding pages is your best tool for finding the service procedure you need. Be certain to observe all Safety information included in these pages.\u003cbr\u003eA schematic of each of the major engine systems is provided at the beginning of the section of the manual devoted to troubleshooting and repairing that particular system.\u003cbr\u003eBasic safety precautions are list in the Safety section of the Doosan DX210 and DX225LCB Excavator Service Manual. Additional safety precautions are list in the Safety section of the owner\/operation\/maintenance publication. Specific safety warnings for all these publications are provided in the description of operations where hazards exist. WARNING labels have also been put on the product to provide instructions and to identify specific hazards.","brand":"Uploader","offers":[{"title":"Default Title","offer_id":53593320456523,"sku":null,"price":58.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2519\/4315\/files\/1-41_7027eb3c-7a03-4d40-9644-fc84c945411d.png?v=1760374733","url":"https:\/\/manualbull.com\/products\/doosan-dx210-and-dx225lcb-excavator-service-manual-workshop-guide","provider":"ManualBull","version":"1.0","type":"link"}